Portable, single trace oscilloscope.
-
Frequency range : 0 Hz to 20 MHz (-3dB).
-
Operating modes : channel Y, XY.
-
Time base : 17 calibrated steps from 50 mS / div to 0.2
µS / div.
-
Trigger : Y or external.
-
Maximum imput voltage : 250 V (DC+AC).
-
Sensitivity : 10 mV / div to 5V / div.
-
Accuracy in calibrated position ± 5%.
-
Has perfect function of trigger.
-
Power supply : 220V.